Last reviewed: November 21, 2026 (UTC)
The answer depends on what you mean by “uses the most.” A national total adds electricity across millions of homes, while a per-home average describes homes that use a particular end use. We use the latest detailed U.S. household data to show both views, explain why your own ranking can differ, and point to safe ways to investigate your usage.
How the ranking is measured
The latest U.S. Energy Information Administration (EIA) survey with detailed household end-use consumption is the 2020 Residential Energy Consumption Survey (RECS). EIA says its 2024 consumption-and-expenditure tables are scheduled for spring 2027, so 2020 remains the latest detailed national breakdown available.
The 2020 RECS covers occupied primary residences in the 50 states and Washington, D.C. EIA’s 2020 RECS methodology says it excludes vacant and seasonal units, second homes, and group quarters such as military barracks, while housing units on military installations are included. The national estimates represent 123.53 million occupied primary housing units. EIA’s site-use measure includes electricity generated by on-site solar panels and used at home. These totals describe U.S. residential consumption, not one home’s bill or the electricity purchased from utilities alone. EIA’s CE4.1 national table reports 1,305 billion kWh of residential site electricity in 2020 and 631 billion kWh in the broad “other” category. “Other” combines many uses, not a single appliance or useful comparison. The table below ranks the largest named categories.
Largest named U.S. electricity uses, ranked by annual total
Among named end uses, air conditioning has the largest national total, followed by electric space heating and water heating. Refrigerators are next.

| Rank among named end uses | End use | 2020 U.S. total | Share of U.S. site electricity | Average per household using that end use |
|---|---|---|---|---|
| 1 | Air conditioning | 253.8 billion kWh | 19.5% | 2,318 kWh/year |
| 2 | Electric space heating | 161.1 billion kWh | 12.3% | 2,484 kWh/year |
| 3 | Electric water heating | 156.2 billion kWh | 12.0% | 2,706 kWh/year |
| 4 | Refrigerators | 103.1 billion kWh | 7.9% | 839 kWh/year |
| 5 | Lighting | 80.8 billion kWh | 6.2% | 654 kWh/year |
| 6 | TVs and related equipment | 75.7 billion kWh | 5.8% | 632 kWh/year |
| 7 | Clothes dryers | 55.9 billion kWh | 4.3% | 680 kWh/year |
EIA publishes the detailed end-use totals directly in billion kWh in its CE5.1a totals and CE5.1b totals. Shares use the 1,305-billion-kWh national total and are rounded. Average annual use per household using each electric end use comes from EIA’s CE5.3a averages and CE5.3b averages.
The total and average columns answer different questions. National totals include every occupied primary residence, including homes without electric space heating or electric water heating. The average column covers households that use electricity for the listed end use. That is why electric water heating uses more per participating household than air conditioning, even though air conditioning uses more electricity across the country. The full-home average is a separate benchmark; we cover it in our whole-home electricity guide.
EIA keeps related equipment in separate rows. For example, its air-conditioning total does not combine air handlers for cooling or ceiling fans, and “TVs and related equipment” includes connected devices such as streaming boxes and game consoles. The top seven categories add up to about two-thirds of U.S. residential site electricity; many smaller uses make up the rest.
Why a home’s ranking can look different
Climate affects how long heating and cooling run. EIA’s CE5.3a regional averages show that households using electric air conditioning in the South used 3,304 kWh per year on average, compared with 1,395 kWh in the Northeast. A regional average can shift because of outdoor temperatures, cooling seasons, home size, equipment, and thermostat habits.
The same table’s climate averages for households using electric space heat show annual use of 2,876 kWh in very-cold and cold climates, compared with 1,914 kWh in hot-humid climates. Weather can move heating or cooling ahead of otherwise steady loads, changing the order in an individual home.
Fuel choice changes the electric ranking too. A home with gas, propane, or oil space heat does not record that heating energy in its electric space-heating total. The same applies to water heating. In those homes, cooling, refrigeration, dryers, and any added electric loads can take a larger share of the electricity use. In an all-electric home, space heating or hot water may sit near the top. An electric vehicle, pool pump, hot tub, or second refrigerator can change a home’s ranking even though it is not one of the biggest national categories.
The RECS ranking describes electricity consumption, not total home energy across all fuels. It also does not predict what an appliance costs to run, since rates vary. If you are estimating the running cost of one system, our heat pump electricity cost guide treats that device-specific question separately.
Kilowatt-hours and peak draw are different
Watts and kilowatts describe how fast a device uses power at a moment. A kilowatt-hour (kWh) measures energy used over time. EIA’s guide to measuring electricity explains the distinction.
For example, a 1.5-kW appliance running for 10 minutes uses 0.25 kWh. A 100-watt load running for 24 hours uses 2.4 kWh. The second load has a lower draw, but it uses almost ten times as much energy over the day. That is why a short, high-wattage burst may matter for a momentary peak, while a lower-power device that runs for hours can use more energy over a month or year.
This ranking is based on annual kWh, not the highest instantaneous draw, a home’s peak demand, or an appliance’s bill cost. Long runtime and seasonal patterns matter as much as how many watts a device draws while it is on.
Find your own biggest loads safely
Compare kWh across utility bills with similar billing periods, or use hourly and interval data in your utility account if it is available. A plug-in meter can help measure an accessible cord-and-plug appliance when used within the meter’s rating.
Hardwired appliances and panel-level monitoring need a different approach. The CPSC panel-safety warning advises consumers not to open a panelboard or circuit-breaker compartment because doing so can expose live wires and pose an electrocution hazard. Use a qualified electrician for panel-level monitoring or other work inside the panel.
For whole-home and circuit-level options, use our home energy monitor guide to choose a measurement route that fits your home and keeps panel work with a professional.